Insulation & Refractory

Cryogenic Insulation — Cellular Glass (Foamglas)

Cellular glass — closed-cell, non-absorbent insulation. Default choice for cryogenic & cold service down to –269 °C.

Category
Insulation & Refractory
Subcategory
Cold / Cryogenic Insulation
Applicable standards
5
Issuing bodies
4

Description

Cellular glass — closed-cell, non-absorbent insulation. Default choice for cryogenic & cold service down to –269 °C.

Applicable Standards (5)

ASTM — 2 standards

ASTM C552 Cellular Glass Thermal Insulation
Edition: C552-22 Region: USA, Global
Cellular glass (Foamglas-type) insulation — preferred for cold/cryogenic service down to about −260 °C; non-combustible, closed-cell, water-impermeable.
Key requirements (8)
  • Cellular glass thermal insulation — Foamglas™ class material.
  • Closed-cell, 100% inorganic glass foam — non-absorbent (zero water uptake).
  • Service temperature: –269 °C to +482 °C (cryogenic to hot service).
  • Thermal conductivity: ~0.040 W/m·K at 24 °C; ~0.033 at –40 °C.
  • Compressive strength: 414 kPa (Type II), 690 kPa (Type IV) — load-bearing capable.
  • Density: ~120 kg/m³.
  • Default cryogenic insulation under cellular glass-cellular glass joints; resists liquid water ingress.
  • Non-combustible per ASTM E136.
Note: Default cold-service insulation for cryogenic LNG / ethylene / ammonia and cold-box applications.
ASTM C585 Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing
Edition: C585-10 (R2021) Region: USA, Global
Standardized pipe-insulation sizing tables.

CINI — 1 standard

CINI Manual Insulation for Industries (CINI Manual)
Edition: Living manual Region: Europe, Global
Dutch industrial insulation manual — hot, cold, cryogenic, fire-protection, personnel-protection. Widely adopted across Europe and global EPC projects.
Key requirements (6)
  • Dutch / European specification for industrial insulation manual.
  • Sheet 2.1.01 onward: design data for hot insulation.
  • Sheet 3.1.01 onward: cold insulation including cryogenic.
  • Vapor barrier integrity test methods for cold service.
  • Materials: cellular glass, PIR, mineral wool, aerogel guidance.
  • Joint sealing details for cold insulation continuity.

BSI — 1 standard

BS 5970 Code of practice for thermal insulation of pipework, ductwork, vessels and equipment in the temperature range −100 °C to +870 °C
Edition: 2012 Region: UK, Global
Application code for hot and cold thermal insulation in industrial service.
Key requirements (6)
  • Code of practice for thermal insulation of pipework, ducts, vessels.
  • Covers hot insulation, cold insulation, personnel protection, frost protection.
  • Thickness selection charts based on heat loss / surface temperature targets.
  • Vapor barrier requirements for cold service detailed.
  • Cladding / metal jacketing specifications.
  • Personnel protection target: surface temperature ≤ 60 °C.

BIS — 1 standard

IS 14164 Industrial Insulation Work — Code of Practice
Edition: 2008 (R2018) Region: India
Indian application code for industrial insulation (hot and cold).